Northern Lights · Reference for the YMH Engineer · Published 24 Jul 2026 · Updated 14 Nov 2026

Northern Lights Operator's Manual OM844W2 (M844W2, M844LW2; 10/09), oil (p.14, SP2) "Change the engine oil and oil filter after 50 hours of operation." "Change the oil and filter again at 100 hours using the oil recommended in the above diagram." "After this, change oil and filter every 250 hours." Its Servicing Schedule Chart (p.12) note 1, for the items it marks: "Perform all maintenance once a year even if hour level has not been reached." The chart lists "SP22 Inspect condition of exhaust elbow" under every 500 hours.

Fuel filters (p.16, SP7-9), primary: "Change the element as often as necessary or every 500 hours." "Change secondary fuel filter every 500 hours." Cooling (p.20, SP14-15): "Flush the cooling system every 2500 hours or every 12 months, whichever comes first." "Use 50% distilled water / 50% ethylene glycol antifreeze mix." "Clean the heat exchanger core once a year or after 2500 hours of operation." Impeller (p.20, SP17): "Change the seawater pump impeller every 1000 hours, or as needed."

Valves and belt (p.15, SP5-6): "Adjust valve clearance after 1000 hours or as needed." "Clearance on both intake and exhaust valves should be 0.008 in. (0.2 mm)." "Check the tension and wear on the V-belt daily." Injectors (p.19, SP11): "Injectors should be checked every 1000 hours." Break-in load (p.9): "Maintain at least a 75% load on your generator set for the first 100 hours."

Northern Lights OM944T (M944T, M38CR2; OM944T3 5/19), zinc electrodes (p.28, SP20) "Check it faithfully every 250 hours." "If more than 50% of the electrode is corroded away, replace it with a new zinc." Impeller (p.28, SP19): "Change the raw water pump impeller every 500 hours, or as needed." Valve clearance (p.18, chart note 8): "Valve clearance = .25 mm (0.0098”)."

V-belt (p.21, SP5): "Check the tension and wear on the V-belt after every 50 hours." Coolant (p.27, SP16-17): "Flush the cooling system every 2000 hours or every 12 months, whichever comes first." "The antifreeze should not contain amine, silicate, or borate." "Use 50% water / 50% (maximum) ethylene glycol antifreeze mix." For SP17, OM944T chart note 7 (p.18) reads "Or every 2 years."

Winterizing (p.30, SP23), "For engines not going to be used for more than 3 months:" "Drain fresh water and seawater cooling systems completely. Flush fresh water systems and refill with the proper antifreeze mixture." Northern Lights OM-C3 (M50C13, M80C13, M65C13, M99C13, M120C13, M150C13; 11/21, p.14), under "Lightly Loaded Applications Post Break-In": "For a generator application, increase the load to 50% load for a minimum of 10 minutes every 3 hours."

Source: Northern Lights Operator's Manual OM844W2, models M844W2 and M844LW2, OM844W2 10/09, p.9, p.12, p.14, p.15, p.16, p.19, p.20, https://www.northern-lights.com/media/PDFs/manual_pdfs/OM844W2.pdf (accessed 2026-11-14); Northern Lights Operator's Manual OM944T, for Models M944T and M38CR2, OM944T3 5/19, p.18, p.21, p.27, p.28, p.30, https://www.northern-lights.com/media/PDFs/manual_pdfs/OM944T.pdf (accessed 2026-11-14); Northern Lights Operator's Manual OM-C3, for Models M50C13, M80C13, M65C13, M99C13, M120C13 and M150C13, OM-C3 11/21, p.14, https://www.northern-lights.com/wp-content/uploads/2021/12/OM-C3.pdf (accessed 2026-11-14)

Keep this engine's log in Yacht Masters Hub