A life raft has to be opened, tested and repacked by an authorized service station on a fixed schedule. You can't do it yourself. How often depends on who made the raft and what kind of boat carries it. Most recreational rafts from the big makers are due every 3 years, some newer ones every 5. Rafts approved by the US Coast Guard for inspected or SOLAS vessels are due every 12 months. Your raft's service label and owner's manual have the final word.
How often does a life raft need servicing?
Here is what each maker says for its current recreational rafts:
| Maker | Interval the maker gives | Source |
|---|---|---|
| Viking (RescYou range) | Every 3 years ("VIKING recommends 3-year service intervals") | https://www.viking-life.com/industries/yachting/liferafts-yachting/servicing/ |
| Revere (Coastal / Offshore Commander 3.0) | First service 3 years after purchase, then every 3 years | https://reveresurvival.com/wp-content/uploads/2021/10/95-43024-101BK-Rev-A-Commander-3.0-Owners-Manual.pdf |
| Revere (Elite Series) | First service 3 years after purchase, then every 3 years | https://reveresurvival.com/wp-content/uploads/2021/06/41080-1BK-Rev.-C-Booklet-Version-1.pdf |
| Winslow (marine rafts) | "A full 3 years between scheduled maintenance" (vacuum packed) | https://www.winslowliferaft.com/marine-liferafts |
| Switlik (CPR, OPR, MRP-10, SAR-6) | 5-year recommended interval | https://switlik.com/pages/faqs |
Two things to watch:
- Same brand, different models. The Switlik SAR-6 is sold in both a 5-year and a 3-year configuration (https://switlik.com/products/sar-6-transoceanic). Switlik asks owners to send the full part number and serial number if unsure (https://switlik.com/pages/faqs).
- Older rafts get tested harder. Revere's service stations run a gas inflation test every 5 years, and floor seam and extra pressure tests at 10 years, with "annual service intervals thereafter" (https://reveresurvival.com/life-raft-service/).
Recreational rafts vs USCG and SOLAS rafts: why the intervals differ
The sources disagree because they cover different rafts, so here is the plain version:
What ISO 9650 covers. ISO 9650 is the International Organization for Standardization's standard for inflatable liferafts on small craft. The current edition, ISO 9650-1:2022 (published May 2022), sets minimum requirements for design, performance, marking and test methods for Type 1 and Type 2 inflatable liferafts carrying 4 to 16 people, intended for small craft with a hull length of up to 24 m and for launching from a height not exceeding 6 m (https://www.iso.org/standard/80963.html). It replaces the 2005 editions, when Type I was in ISO 9650-1:2005 and Type II was in a separate part, ISO 9650-2:2005; both of those parts were withdrawn on 6 May 2022 (https://www.iso.org/standard/37478.html, https://www.iso.org/standard/37479.html). A third part, ISO 9650-3:2009, covers materials only and remains current (confirmed 2024) (https://www.iso.org/standard/45643.html). ISO's public abstract does not set a service interval, and no Viking, Revere, Winslow or Switlik page we opened attributes one to the standard. For ISO-certified recreational rafts, follow the maker: Viking recommends 3 years on its RescYou range, which it certifies as ISO 9650-1 Type 1 (Ocean and Pro, for ocean cruising) or ISO 9650-1 Type 2 (Coastal, for coastal waters near rescue points) (https://www.viking-life.com/industries/yachting/liferafts-yachting/choosing-your-liferaft/; Viking RescYou Ocean datasheet, ED. 09/2025); Revere's ISO 9650-1 Offshore Commander 4.0, "designed, tested and manufactured to ISO 9650" for offshore conditions with strong winds and significant waves, lists a 3-year inspection interval (https://reveresurvival.com/product/offshore-commander-4-0-life-raft/).
- Recreational (leisure) rafts follow the maker's schedule above: usually 3 years, 5 for some newer models. Many of these rafts are built to ISO 9650, but the service interval still comes from the maker, not from ISO's public abstract.
- USCG-approved rafts (the kind required on inspected and SOLAS vessels) carry a service sticker that expires 12 months after repacking (46 CFR 160.151-57(n), https://www.ecfr.gov/current/title-46/section-160.151-57). A brand-new raft can go up to 2 years before its first service, but only if its dated gear won't expire first and it is not going on a SOLAS vessel (same section, (n)(1)).
- Inspected vessels must service each inflatable life-saving appliance within 12 months of packing and of each service. The service can slip to the vessel's next scheduled inspection, but by no more than 5 months (46 CFR 199.190(g), https://www.ecfr.gov/current/title-46/section-199.190).
For a private recreational boat: the federal equipment rules for recreational boats (33 CFR 175) cover life jackets, visual distress signals, ventilation and fire extinguishers. They do not include a life raft (https://www.ecfr.gov/current/title-33/part-175). So for most private owners the maker's interval is the one that counts. Race rules, charter contracts or insurers may set their own; check with them.
What "recertification" means
Recertification is the same thing as a service and repack. When a raft passes, the station records it and sends it back with paperwork:
- Viking: the logbook inside the raft is filled in, the container is relabeled, and "a servicing certificate is issued" (https://www.viking-life.com/industries/yachting/liferafts-yachting/servicing/).
- Winslow: results go on a service inspection report and "a service validation certificate is issued" (https://www.winslowliferaft.com/service/liferaft-service).
- USCG-approved rafts: the station marks the service date on the raft, puts a tamper-proof sticker on the container showing the expiry year and month, and gives the owner a certificate with the raft's serial number and service date (46 CFR 160.151-57(m) and (p), https://www.ecfr.gov/current/title-46/section-160.151-57).
What happens at a life raft service station
The steps are much the same across makers:
- Open and unpack. The container or valise is opened, the inflation system disconnected and the raft taken out (Viking; Revere, https://reveresurvival.com/life-raft-service/).
- Inflate and leak test. The raft is inflated with air and each chamber is pressure tested for 60 minutes. At Revere, the final pressure after correcting for temperature and air pressure must be at least 95% of the start pressure. Inflatable floors are tested too (Viking; Revere).
- Check the gas cylinder. It is weighed to confirm it is still full (Viking; Revere; Winslow). On USCG-approved rafts, a cylinder that has lost more than 5% of its charge must be recharged (46 CFR 160.151-57(b)(12)). The cylinder's hydrostatic test date is checked; if overdue, it must be retested under US DOT rules (Revere Commander 3.0 manual).
- Inspect the fabric and seams inside and out (Viking; Winslow).
- Check the emergency pack. Expired items are replaced (Viking; Revere; Winslow). On USCG-approved rafts, anything with less than 6 months left is replaced, and batteries are replaced if expired or undated (46 CFR 160.151-57(b)(5) and (b)(6)).
- Repack, seal, label and certify (Viking; Winslow).
Winslow says it will open and inspect your raft, then "contact you to discuss all service needs prior to recertification" (https://www.winslowliferaft.com/service/liferaft-service). Expect a call if parts or gear need replacing.
When to book your raft in
- By the date on the service label. Revere's Commander 4.0 manual says the sticker on the container or in the valise pocket shows the next service date, and that the date can vary by country and sailing area (https://reveresurvival.com/wp-content/uploads/2025/04/OWNER-MANUAL-REVERE-COMMANDER-4.0.pdf).
- Before a season or passage where you'll rely on it, so the raft is back aboard in time. Many stations need the raft for a while; ask yours how long.
- Don't open or test-inflate it yourself. Revere: "Never attempt to open the raft package and service the raft yourself," and test-inflating "may damage parts of the raft" (https://reveresurvival.com/wp-content/uploads/2021/10/95-43024-101BK-Rev-A-Commander-3.0-Owners-Manual.pdf).
- Use a station authorized for your brand. Viking lists 280+ stations (https://www.viking-life.com/service/find-service-station/). Revere and Winslow say only their authorized stations should service their rafts (Revere manual above; https://www.winslowliferaft.com/service/liferaft-service).
- Keep it on schedule for warranty. Revere says you must keep to the servicing deadlines to keep its warranty (Commander 4.0 manual above).
Cost: Viking says service costs "vary from country to country" and to ask your local station (https://www.viking-life.com/industries/yachting/liferafts-yachting/servicing/). We found no named, dated typical price range from a maker, regulator, BoatUS or West Marine page, so we don't give one.
What we don't cover here
Hydrostatic release units and EPIRBs have their own service rules; see our EPIRB and PLB page. Aviation rafts follow aviation rules; the one maker note we found is that Switlik's FAA TSO-approved variants of its CPR and OPR also come with a 5-year recommended interval (https://switlik.com/pages/faqs).
Source: ISO 9650-1:2022, ISO 9650-1:2005, ISO 9650-2:2005 and ISO 9650-3:2009 (iso.org); Viking, Revere, Winslow and Switlik manufacturer pages, manuals and the Viking RescYou Ocean datasheet (ED. 09/2025); 46 CFR 160.151-57; 46 CFR 199.190; 33 CFR 175. Checked 15 Nov 2026.